Often times, the flow rate for the residential sprinkler system exceeds this flow rate. A 5/8-inch water meter is rated for a maximum flow rate of 20 gpm. Why the larger size? Because smaller meters cannot move enough water to supply the sprinklers. Normally, a minimum 3/4-inch water meter will be required when multipurpose residential sprinkler systems are installed. This additional 5 gpm ensures that the service line from the supply source to this separation point is sized to support both domestic flow and fire sprinkler flow as needed. In these designs, a five-gallon per minute (gpm) flow must be added at the point where the system piping separates to feed the individual units. The exceptions to this rule are cases in which the water-service piping supplies more than one dwelling unit. The resulting system should be several percentage points less expensive - from an installed-cost standpoint - than the two systems it replaces if they were run independently. As a result, one redundant piping system is eliminated, reducing material and labor costs, as well as reducing construction and coordination time on site. A relatively new option in the residential fire sprinkler market, these systems are quickly gaining acceptance and even preference in many municipalities.Ī multipurpose residential fire sprinkler system, by definition, combines the domestic potable cold-water system with the residential fire sprinkler system. Many developers and builders are unaware of the cost reductions that they and their communities can achieve by installing multipurpose residential fire sprinkler systems in their projects. Their resistance is usually rooted in misconceptions regarding either cost or performance. Residential fire sprinkler systems seem to be an obvious answer to many of these obstacles, yet many groups object to their installation.

#RESIDENTIAL FIRE SPRINKLER SYSTEM DESIGN MANUAL#

New residential growth requires large water mains, wide roads and closely spaced fire hydrants for manual fire suppression. Los Angeles Ave.Public fire protection is a key cost. If additional work is required please call a licensed fire sprinkler contractor for service 805.583.5000, or Contact Us by using the simple form below.Ĭontact Us 805.583.5000 or you may use the easy form.įierce Fire Protection,Inc. If no leaks are present, fully open control valve.ģ.

residential fire sprinkler system design

Note: the alarm bell will sound while the system is filling. * Close the main drain and inspectors test valves. The fire department or the homeowner must insure all repairs have been made and water must be returned to the system. (All heads must be installed with teflon tape and with wrench provided.)Ģ.

#RESIDENTIAL FIRE SPRINKLER SYSTEM DESIGN INSTALL#

The fire department will install a new fire sprinkler head from your spare head box normally located in the garage.

residential fire sprinkler system design

After this is determined, The fire department or homeowner must shut off the water at the sprinkler control valve or at the meter. In the event of a fire, the local fire department must first determine that the fire is fully extinguished. In the event that remodeling or construction has altered the original configuration, additional sprinklers should be installed, as required, to maintain protection level.ġ. DO NOT PAINT THE FIRE SPRINKLERS PAINT CAN CLOG THE SPRINKLER AND PREVENT PROPER OPERATION.ĥ. Replace any sprinkler exhibiting corrosion or damage.Ĥ. Nothing should be hung or attached to the sprinkler unit that would disrupt the spray pattern.

#RESIDENTIAL FIRE SPRINKLER SYSTEM DESIGN FREE#

Keep the fire sprinklers free of dust build-up and any other form of debris or contamination that may impede operation. If the alarm fails to ring after this period, contact a licensed fire sprinkler contractor for an inspection.ģ. On a yearly basis, open the system test valve until the alarm bell begins to ring a delay of 30 to 60 seconds is normal. If the gauge reads zero, contact a licensed fire sprinkler contractor for an inspection.Ģ.

residential fire sprinkler system design

On a regular basis, observe the system’s water pressure on the riser gauge. Under normal circumstances, your fire sprinkler system will require minimal maintenance, with exception of the following:ġ.

residential fire sprinkler system design

Summarized below are maintenance and emergency procedures: In the event a fire sprinkler is activated, the alarm bell on the outside of your home will ring, alerting the occupants, at which time they should exit the home immediately. The installed sprinklers are activated individually by heat i.e., Only the sprinklers in the vicinity of the fire become active. The purpose of this type of system is to improve the chance for occupants to escape or be evacuated if there is a fire within the home. RESIDENTIAL FIRE SPRINKLER MAINTENANCE AND EMERGENCY INSTRUCTIONSĪn NFPA 13D residential fire sprinkler system has been installed in your home, in accordance with local codes. Residential Fire Sprinkler Design, Installation, Service & Repairs in the Southern the California areas.